What was found
DURING SCHEDULED SC CHECK, FOUND 2 CRACK INDICATIONS BETWEEN STR 7R AND 5L ON AFT ROW OF FASTENERS OF BS 1016 AFT PRESSURE BULKHEAD. REMOVED DAMAGED WEB, FABRICATED, FIT, DRILLED AND INSTALLED REPAIR PARTS PER TRAMCO EWO 99-0138.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED SC CHECK, FOUND 2 CRACK INDICATIONS BETWEEN STR 7R AND 5L ON AFT ROW OF FASTENERS OF BS 1016 AFT PRESSURE BULKHEAD. REMOVED DAMAGED WEB, FABRICATED, FIT, DRILLED AND INSTALLED REPAIR PARTS PER TRAMCO EWO 99-0138.