As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RBL27 FLOOR BEAM AT FS559.0 HAS CORROSION (C-CHECK RO 9/13/2023) REMOVED CORROSION FROM RBL 27 FS559 FLOOR BEAM FLANGE REF CRJ200 SRM 51-21-06 FOUND TO BE OUT OF LIMITS. REF REO 601R-53-00-005, REV-B, DATED 2011-01-06. REPAIRED AREA PER REO 601R-53-41-3182 REV -- DATED 2023-07-31. COMPLIED WITH SKYWEST TASK CARD 51-900-1003-SKY. SEE CONTINUATION CARD FOR DETAILS