What was found
SIGNS OF CORROSION ON MULTIPLE FASTENERS UNDER FLOOR PANEL RH SIDE IN AND/OR AROUND FASTENERS AT FS428 (C-CHECK RO 5/13/2024) REPAIRED CORROSION DAMAGE @ FS 428.00 R/H FLOOR SILL PANEL NUT PLATE IAW REO 601R53-41-666 REV-C DATE: 2012-11-06. NDT PERFORMED BY BARON NDT, LLC, FAA. CRS# 5NDR545D REPORT # S030124-12 P.O. # 171069 DATED: 01 MAR 2024. SEE REPORT FOR DETAILS. CRJ 200 SRM 51-21-11, 51-25-06, 51-25-16 ALSO UTILIZED FOR REPAIR.