What was found
CABIN INTERIOR CORROSION AT FS942.00 ON AFT SIDE FACE AND FLANGE BETWEEN STGR26R AND STGR25R AS MARKED (C-CHECK RO 8/24/2024) REMOVED DAMAGE FROM UNDERFLOOR FRAME, FS 942.00, BETWEEN STGR 25R - 26R REF CRJ900 SRM 51-21-06-001-001-A01. FOUND TO BE OUT OF LIMITS. REPAIRED DAMAGED FRAME PER REF CRJ 900 SRM 53-00-06-201-001-001-A03 AND CRJ900 SRM 51-42-06-001-001-A01. COMPLIED WITH TASK CARD 51-900-1002-SKY.