What was found
FOUND CORROSIOIN ON RH PRESSURE FLOOR SILL AT FS439.00 (FILED OPEN)REPAIRED CORROSION DAMAGE ON RH PRESSURE FLOOR SILL AT FS439.00 WITH REFERENCE TO REO 601R-53-41-666 REV "C" DATED 2012-11-06. PERFORMED UT REMAINING THICKNESS MEASUREMENT WITH REFERENCE TO NDTM PART 4 51-00-001 AND FOUND TO BE WITHIN ACCEPTABLE LIMITS OF REO 601R-53-41-666. PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 1 51-20-06 AND NDTM PART 6 53-00-096 WITH NO DEFECT FOUND. COMPLIED WITH TASK CARD 51-900-1003. COMPLIED WITH M-337. COMPLETED CORROSION FINDINGS REPORT. REFERENCE CP 28963139 FOR PRESSURIZATION LEAK CHECK.