What was found
FLOOR PANEL LANDING COMMON TO THE FS,280.00 BEAM BETWEEN RBL12 AND LBL12 CORRODED (MARKED). (C-CHECK RO 1/19/2024) INSTALLED NEW FLOOR SUPPORT ANGLE ASSY. P/N CC670-34095 AT FS 280.00 BEAM BETWEEN LBL12 AND RBL 12 REF CRJ 700 SRM 51-42-06-001-001-A01, CRJ 700 SRM 51-42-21-001-001-A01 AND DWG. NO. CC670-34010 REV. K. COMPLIED WITH SKY WEST TASK CARD 51-900-1002-SKY (CL600-2C10) STRUCTURAL MAJOR REPAIR