As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR BEAM LBL9 AT APPROX FS1031 FOUND TO BE CORRODED (C-CHECK RO 1/24/2024) CORROSION ON FLOOR BEAM AT LBL9 FS1031.00 FOUND OUT OF LIMITS DUE TO NO DAMAGE ALLOWED PER CRJ700SRM 53-61-43-101-001-A01. REMOVED AND REPLACED FLOORBEAM SECTION AT LBL9 FS1006.00 TO FS1064.00 PER CRJ700SRM 53-00-41-201-001-A01 AND REO 670-53-61-2217 REV -- DATED 2023-12-28. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY. COMPLIED WITH FORM M-337. SEE CONTINUATION FOR DETAILS OF WORK ACCOMPLISHED.