As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR SUPPORT GUSSET AT RBL12 FS280 IS CRACKED (C-CHECK RO 1/30/2024) INSTALLED NEW FLOOR SUPPORT GUSSET AT RBL12 FS280 IAW CRJ700 SRM 51-42-06-001-001-A01 AND DRAWING CC670-33052 REV -G SEE CONTINUATION FOR WORK PERFORMED, COMPLIED WIRTH 51-900-1002-SKY