What was found
FOUND CORROSION ON SEVERAL AREAS OF THE RH PRESSURE FLOOR SILL FS 424.00 , FS449.85 , FS473.15 , FS484.00 , FS513.00 , FS526.00 (FILED CLOSED) BLENDED CORROSION ON THE RH PRESSURE FLOOR SILL FS 424.00 , FS449.85 , FS473.15 , FS484.00 , FS513.00 , FS526.00 WITH REFERENCE TO SRM 51-21-06. PERFORMED UT REMAINING THICKNESS MEASUREMENT WITH REFERENCE TO NDTM PART 4 51-00-001 AND FOUND TO BE ACCEPTABLE PER REO 601R-53-41-3249 REV "--" DATED 2024-08-29 WITH EXCEPTION OF FS 449.85. SEE CHILD CAMP FOR CONTINUATION OF REPAIR TO RH PRESSURE FLOOR SILL AT FS449.85. PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 1 51-20-06 AND NDTM PART 6 53-00-096 WITH NO CRACKS FOUND. COMPLIED WITH REO 601R-53-41-3249 REV "--" DATED 2024-08-29. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLIED WITH M-337. COMPLETED CORROSION FINDINGS REPORT. REFERENCE CHILD CAMP FOR LEAK CHECK.