What was found
INTERCOSTAL FWD OF AVIONICS DOOR LEFT OF STGR27 HAS SIGNS OF CORROSION ON INBD WEB (C-CHECK RO 10/6/2024) (FILED CLOSED)REMOVED AND REPLACED INNER COSTAL FWD AVIONICS DOOR AT STGR 27 IB WEB IAW CRJ700 SRM 51-42-06, 51-42-21, 51-40-11, 51-21-11, 51-25-06, 51-42-13, 51-25-16, 51-41-02, 53-21-23, AMM 52-70-08, 52-42-00, 21-31-00.