What was found
UNDER COCKPIT FLOOR, FWD OF 280 FRAME. FWD JACKING POINT THE LH INTERCOSTAL IS CORRODED. FLAGGED S/N 0657 (C-CHECK RO 10/7/2024) (FILED OPEN)REPAIRED FWD OF F/S 280 FRAME FWD JACKING POINT THE L/H INTERCOSTAL IAW DWG CC670-32050 REV. NC AND REO 670-53-11-2010 REV. -- DATED 2024-09-02 ALL STEPS COMPLIED WITH AND CRJ 700 SRM 51-42-21-001-001-A01 AND CRJ 700 SRM 51-42-06-001-001-A01 AND COMPLIED WITH TASK 51-900-1002-SKY. LEAK CHECK GOOD SEE CONTINUATION CARD FOR DETAILS.