What was found
AFT INTERNAL FUSELAGE FRAME IS CORRODED ON AFT SIDE, LOCATED AT FS879.00 BETWEEN STGR26L AND STGR26R AS MARKED (C-CHECK RO 10/7/2024) (FILED CLOSED)EVALUATED CORROSION ON FRAME AT FS879.00 STGR26L-STGR26R AND FOUND OUT OF LIMITS PER CRJ700SRM 53-51-06-101-003-A01. REPAIRED FRAME SECTION AT FS879.00 STGR25L-STGR25R PER CRJ900SRM 53-00-06-201-001-A03 AND DWG SH670-37060 REV G, IN CONJUNCTION WITH REO 670-53-51-290 REV -- DATE 2024-07-07 GIVING PROVISION FOR USE OF THE CRJ900SRM FOR THIS REPAIR. LEAK CHECK GOOD. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY. SEE CONTINUATION FOR DETAILS.