What was found
FORWARD BAGGAGE BAY INTERNAL STRUCTURE MACHINED FITTING (LBL24) (SH670-33390-1) CORROSION AROUND SCREW HOLES (C-CHECK RO 10/7/2024) (FILED CLOSED)FORWARD BAGGAGE BAY, INTERNAL STRUCTURE, MACHINED FITTING AT LBL24 (SH670-33390-1) REPLACED IAW CRJ 700 SRM 51-42-21-001-001-A01, AND CRJ 700 SRM 51-42-22-001-001-A01 AND REFERENCE DWG SH670-33600 REV. AD FOR FASTENER TYPE. SKY CARD 51-900-1002-SKY-(CL600-2C10)ACCOMPLISHED. SEE ATTACHED CONTINUATION CARD FOR DETAILS.