Service difficulty report · Floor Support · Cndair CL6002B19

Difficulty date
September 23, 2024
Submitted
November 4, 2024
Operation
Air carrier
Aircraft
N221PS
Make and model
Cndair CL6002B19
Aircraft serial
7889
Aircraft time
41,239 hours, 40,623 cycles
Part
Floor Support
Condition
Corroded
Location
Zone 200
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FOUND CORROSION ON LH PRESSURE FLOOR SILL AT FS499.00 (FILED CLOSED)REPAIRED CORROSION DAMAGE ON LH PRESSURE FLOOR SILL AT FS499.00 WITH REFERENCE TO REO 601R-53-41-666 REV "C" DATED 2012-11-06. PERFORMED UT REMAINING THICKNESS MEASUREMENT WITH REFERENCE TO NDTM PART 4 51-00-001 AND FOUND TO BE WITHIN ACCEPTABLE LIMITS OF REO 601R-53-41-666. PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 1 51-20-06 AND NDTM PART 6 53-00-096 WITH NO DEFECT FOUND. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLIED WITH M-337. COMPLETED CORROSION FINDINGS REPORT. REFERENCE CP 28963139 FOR PRESSURIZATION LEAK CHECK.