Service difficulty report · Drain Mast · Cndair CL6002C10
FAA SDR system
- Difficulty date
- September 23, 2024
- Submitted
- November 8, 2024
- Operation
- Air carrier
- Make and model
- Cndair CL6002C10
- Aircraft serial
- 10288
- Aircraft time
- 37,439 hours, 24,335 cycles
- Part
- Drain Mast
- Condition
- Corroded
- Location
- Zone 100
- Stage of operation
- IN
- How discovered
- O
- Nature of condition
- O
- Precautionary procedure
- K
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON CHANNEL FOR DRAIN MAST LOCATED IN CABIN UNDERFLOOR BETWEEN FS 333.00 - 349.00, STGR 24R - 25R (C-CHECK RO 11/6/2024) REMOVED AND REPLACED DRAIN MAST CHANNEL P/N SH670-32270-1. REF. CRJ700 SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001-A01 AND DWG# SH670-32250 REV. K. LEAK CHECKED GOOD.COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY (CL600-2C10) STRUCTURAL MAJOR REPAIR (**RII**)