What was found
CORROSION FOUND ON FRAME 581 AROUND STR 27 CUTOUT, FWD AND AFT FACE OF ATTACH FLANGE AND WEB CAMP 29321370 (C-CHECK RO 2/26/2025) REMOVED AND INSTALLED NEW FRAME @FS581.00 STR27 AND STR20R IAW CRJ 900 SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001 A01 REV 38 DATE JUL-25-2020 AND DWG# SH690-33200 REV -N AND COMPLIED WITH TASK CARD 51-900-1002-SKY AND LEAK CHECK GOOD