As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON FLOOR BEAM LBL9 BETWEEN FS 1015.00 - 1069.00. MARKED (C-CHECK RO 2/26/2025) REPAIRED FLOOR BEAM SECTION AT RBL 9.0 BETWEEN F/S 1015 TO F/S 1069 IAW CRJ 900 SRM 53-00-41-201-001-A03 AND COMPLIED WITH ALL STEPS OF REO 690-53-61-1476 REV. -- DATED 2024-12-20 AND COMPLIED WITH TASK CARD 51-900-1002-SKY AND SEE CONTINUATION CARD FOR DETAILS