As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LEFT AFT EMER. EXIT DOOR HAS SPOTS OF CORROSION AROUND SCREW HOLE AT LOWER AFT END (MARKED). (C-CHECK RO 8/21/2025) REPAIRED CORROSION ON LH AFT EMER. EXIT DOOR AROUND SCREW HOLE AT LOWER AFT END. COMPLIED WITH ALL STEPS OF REO 690-52-21-200 REV A DATED 2025-08-14 . COMPLIED WITH TASK CARD 51-900-1002-SKY. SEE CONTINUE CARD FOR WORK PERFORMED.