What was found
DURING AUDIT OF 6YR TASK CARD 53-230-500(DETAILED INSPECTION OF THE GALLEY SERVICE DOOR (FORWARD) SURROUND STRUCTURE, ABOVE FLOOR, INTERNAL - FS319.70 TO FS349.00 (EES)) FOUND FWD LOWER JOINT PLATE AT FS 319.70 - WL 72.00 APPEARS TO BE CORRODED. (C-CHECK RO 8/21/2025) REMOVED FWD LOWER JOINT PLATE AT FS 319.70 - WL 72.00 IAW CRJ900 SRM 51-42-21-001-001-A01 AND INSTALLED FWD LOWER JOINT PLATE AT FS 319.70 - WL 72.00 IAW CRJ900 SRM 51-42-21-001-001-A01 AND DWG # SH670-31950, REV Y AND SH670-31990 REV- NC .COMPLIED WITH TASK CARD 51-900-1002-SKY