What was found
PROVIDE ACCESS FOR F/S 645.FRAME REMOVAL BETWEEN STRG 20 R/H AND STRG 16 R/H FOR STRINGER REPAIR STRG 18 R/H FOR CAMP #30042715 JOB # HN00238242 (C-CHECK RO 8/21/2025) REMOVED AND INSTALLED FRAME F/S 645 BETWEEN STRG 16 R/H AND FACTORY SPLICE AT STRG 20 R/H IAW CRJ 900 SRM 51-42-06-001-001-A01 AND CRJ 900 SRM 51-42-21-001-001-A01 AND CRJ 900 SRM 53-00-06-201-001-A03, PRESSURE LEAK CHECK WAS GOOD,COMPLIED WITH 51-900-1002-SKY