Service difficulty report · Floor Support · Cndair CL6002D24
FAA SDR system
- Difficulty date
- March 22, 2025
- Submitted
- September 9, 2025
- Operation
- Air carrier
- Make and model
- Cndair CL6002D24
- Aircraft serial
- 15102
- Aircraft time
- 31,664 hours, 24,996 cycles
- Part
- Floor Support
- Condition
- Corroded
- Location
- Zone 200
- Stage of operation
- IN
- How discovered
- V
- Nature of condition
- O
- Precautionary procedure
- K
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RH FLOOR SILL IS CORRODED FS280 €“ 319 (C-CHECK RO 09/07/2025)REMOVED AND INSTALLED RH FLOOR SILL BETWEEN FS280.00 - FS319.00. PRESSURE LEAK TEST GOOD. REF - CRJ900 SRM 51-42-06-001-001-A01, CRJ 900 SRM 51-42-13-001-001-A01, CRJ 900 SRM 51-42-21-001-001-A01. AND DWG. NO. SH690-32170 REV. AD COMPLIED WITH 51-900-1002-SKY