What was found
BS 942 FRAME WEB ON THE FWD AND AFT SIDES BETWEEN STR 25L &26L AND THE ATTACHED FLANGE BETWEEN STR 25L €“ 25R ARE CORRODED. (C-CHECK) REMOVED AND INSTALLED NEW FRAME SECTION & SPLICES ON BS.942, BETWEEN STGR 25L & 25RT. REF CRJ900 SRM 53-00-06-201-001-A03. COMPLIED WITH SKYWEST TASK CARD: 51-900-1002-SKY. LEAK CHECK GOOD.