What was found
RIGHT INBD FLAP, OTBD VANE ACTUATOR SHAFT HAS INDENT. (C-CHECK) BLENDED OUT THE DAMAGE ON RT INBD FLAP, OTBD VANE ACTUATOR SHAFT IAW REO 670-57-52-257, REV A. FOUND TO BE IN LIMITS IAW REO 670-57-52-257, REV. A. COMPLIED WITH ALL STEP OF REO 670-57-52-257 REV. A. OPS CHECKED GOOD. COMPLIED WITH 51-900-1002-SKY