What was found
INTERNAL STRUCTURE OF THE REAR FUSELAGE - FLOOR SUPPORT BS 985 TO 1098.20, RBL 9, FLOOR SUPPORT HAS CORROSION PITTING. (C-CHECK) REPAIRED CORROSION ON FLOOR SUPPORT AT FS 985 TO1098.2 & RBL 9. IAW SRM 51-42-21-01-01-A01, SRM 53-00-41-201-001-A03 , REO 690-53-61-1632 REV-, AND DWG MM690-35041, REV AB. COMPLIED WITH SKY CARD 51-900-1002-SKY.