What was found
FOUND CORROSION ON FLOORBEAM, BS 280, LBL 12, UNDER LT CAP ANGLE. REMOVED AND INSTALLED A NEW FLOORBEAM IAW SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001-A01, SRM 51-42-22-001-001-A01 AND DWG CC670-34010, REV -K. COMPLETED SKYWEST TASK CARD 51-900-1002-SKY.