What was found
COMPLY WITH SCHEDULED MAINTENANCE CODE: RA32427-STS EA 30-2016-179 897SK-DTI - S26L HAS CORROSION BTW BS 954 - 969. REPAIRED IAW EA 30-2016-179, REV -, PERFORM NDT LFEC & HFEC PER NDTM PART 1, 51-20-006, EA 30-2016-179, REV A, SEC II DTIR, REPLACED THE STRINGER SECTION IAW REO 690-53-51-516 REV--. COMPLETED SKYWEST TASK CARD 51-900-1002-SKY.