What was found
STRINGER 20R FOUND TO BE CORRODED BETWEEN BS 319.70 - 333, BEHIND ELECTRICAL CONNECTOR BRACKET. REMOVED THE STRINGER IAW SRM 51-42-06-001-001-A01, REV OA, AND 51-42-21-001-001-A01, REV OA. FABRICATED LOCATED AND DRILLED A NEW STRINGER IAW DRAWING SH670-32428-3 AND SAMPLE IAW SRM 51-24-16-001-001-A01 AND 51-40-11-001-001-A01, REV OA. INSTALLED NEWLY FABRICATED STRINGER BETWEEN BS 319 - 333 IAW SRM 51-42-06-001-001-A01, REV OA.