What was found
RIGHT FLOOR SILL BETWEEN BS 280 TO BS 319 SEVERAL AREAS ARE CORROSION. INSTALLED NEW RT FLOOR SILL AT BS 280 TO BS 319 IAW SRM 51-42-06-001-001-A01, SRM 51-42-13-001-001-A01, SRM 51-42-21-001-001-A01 AND DWG SH690-32170 REV AD. COMPLIED WITH 51-900-1002-SKY. LEAK CHECKS GOOD.