As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
STR 20R IS CORRODED ON THE WEB AND FREE FLANGE BETWEEN FS364 & 379. REMOVED AND REPLACED CORRODED STRINGER AND FLANGE WITH NEW STRINGER AND FABRICATED FLANGE AT STR 20R PER REO 690-53-21-2042 REV--. ALL STEPS OF REO COMPLIED WITH IN THEIR ENTIRETY. PERFORMED LEAK CHECK OF REPAIRED AREA. NO LEAKS FOUND. SKYCARD 51-900-1002-SKY COMPLIED WITH.