What was found
AFT CARGO FLOOR SUPPORT, RBL 9, BETWEEN BS 559+64 AND BS.559+80 HAS SPOTS OF CORROSION. BLENDED REPORTED CORROSION ON THE FLOOR SUPPORT INNER CAP FLANGE BETWEEN BS 559+64 AND BS 559+80 IAW SRM 51-21-06. BLENDED AREA WAS FOUND OUT OF LIMITED IAW SRM 53-31-43 AND SRM 53-00-00 FIG 10, ACCOMPLISHED A FLOOR SUPPORT INNER CAP FLANGE REPAIR IAW SRM 53-00-43, REPAIR 01, FIG 203, SHEET 2, SRM 51-42-13, & SRM 51-42-06, REV 39. SKYWEST TASK CARD 51-900-1003-SKY.