As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
HYD PUMP 2B MESSAGE ILLUMINATED ON APPROACH. HYDRAULIC SYNOPTIC PAGE SHOWED 0 PERCENT FLUID, TEMP 40 DEGREES WITH HYD PSI OF 3000. REPLACED NR 2 HYD SYSTEM TUBE ASSY, CASE DRAIN AND TUBE ASSY, PUMP PRESS LINE. SERVICED NR 2 HYD SYSTEM. NO LEAKS NOTED. OPS CHECK GOOD.