What was found
FS 280.00 RT FLOORBEAM RBL 9.0 OB ATTACH ANGLE CRACKED. (ITEM FOUND AT C-CHECK INSPECTION.) ANGLE REPLACED IAW CRJ SRM 51-40-11, 51-42-06, 51-42-20 AND 51-23-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FS 280.00 RT FLOORBEAM RBL 9.0 OB ATTACH ANGLE CRACKED. (ITEM FOUND AT C-CHECK INSPECTION.) ANGLE REPLACED IAW CRJ SRM 51-40-11, 51-42-06, 51-42-20 AND 51-23-00.