What was found
STAB CHANNEL 2 FAILED. REPLACED HST ACTUATOR AND MCU IAW CRJ MM 27-42-01, 27-42-05. OPERATIONAL CHECK GOOD, P/N 7062-3 S/N OFF 1077.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STAB CHANNEL 2 FAILED. REPLACED HST ACTUATOR AND MCU IAW CRJ MM 27-42-01, 27-42-05. OPERATIONAL CHECK GOOD, P/N 7062-3 S/N OFF 1077.