What was found
AFTER TAKEOFF GOT GEAR UP DISAGREE AND THE NOSE GEAR WAS STILL DOWN. RETURNED TO FIELD. PERFORMED NOSE SHOCK STRUT SERVICE IAW ST 12-710-002. OPERATIONAL CHECKS GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFTER TAKEOFF GOT GEAR UP DISAGREE AND THE NOSE GEAR WAS STILL DOWN. RETURNED TO FIELD. PERFORMED NOSE SHOCK STRUT SERVICE IAW ST 12-710-002. OPERATIONAL CHECKS GOOD.