What was found
FS 280 FLOORBEAM CLIPS 2EA LBL CRACKED, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED REPLACEMENT CLIPS PER CRJ200 DWG 601R3113 AND SRM 51-40-06/51-24-16 PG 1-7.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FS 280 FLOORBEAM CLIPS 2EA LBL CRACKED, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED REPLACEMENT CLIPS PER CRJ200 DWG 601R3113 AND SRM 51-40-06/51-24-16 PG 1-7.