What was found
INTERCOSTAL CLIP AT FS 559 CRACKED UNDER FLOOR PANEL 281BLF, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED NEW INTERCOSTAL CLIP IAW REO NR 601R-53-21-128 AND PER CRJ200 SRM 51-42-20.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INTERCOSTAL CLIP AT FS 559 CRACKED UNDER FLOOR PANEL 281BLF, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED NEW INTERCOSTAL CLIP IAW REO NR 601R-53-21-128 AND PER CRJ200 SRM 51-42-20.