What was found
PAX DOOR FWD WEB CRACKED AT STEP 5 BASE END ADJACENT TO STEP 4 FROM THE BOTTOM, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED DOUBLER AND REPAIR ANGLES PER REO 690-52-11-104 REV B REPAIR ZONE 2 REO 670-52-11-104 REV B COMPLETE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PAX DOOR FWD WEB CRACKED AT STEP 5 BASE END ADJACENT TO STEP 4 FROM THE BOTTOM, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED DOUBLER AND REPAIR ANGLES PER REO 690-52-11-104 REV B REPAIR ZONE 2 REO 670-52-11-104 REV B COMPLETE.