What was found
FLT 2585 - APU WOULD NOT START AND CABIN SMELLED OF FUEL. REPLACED BOTH IGNITER PLUGS WITH SERVICEABLE UNITS IAW AMM 49-41-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLT 2585 - APU WOULD NOT START AND CABIN SMELLED OF FUEL. REPLACED BOTH IGNITER PLUGS WITH SERVICEABLE UNITS IAW AMM 49-41-05.