What was found
GEAR DISAGREE ON APPROACH, NOSE GEAR REMAINED UP. RAN QRH. NOSE GEAR EXTENDED WITH CYCLE OF GEAR HANDLE. LANDED NORMALLY. SWUNG GEAR NUMEROUS TIMES WITH NO DISCREPANCIES NOTED, UNABLE TO DUPLICATE DISCREPANCY, PSEU INTERROGATION INCONCLUSIVE ON CAUSE. REPLACED NLG PRIORITY VALVE FOR TROUBLESHOOTING, IAW AMM. PERFORMED EMERGENCY EXTENSION AND LANDING GEAR SWINGS WITH NO DEFECTS NOTED. PN ON, OFF 4622, SN ON 1407A, SN OFF 1560A.