What was found
RIGHT FLOORBEAM FS 1000.0 CORRODED BETWEEN RBL 27 AND FLOOR SILL. (C-CHECK) REPAIRED RT FLOORBEAM FS 1000.0 SUPPORT ANGLE BETWEEN RBL 27 AND FLOOR SILL IAW REO.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.