AFT FLOOR SUPPORT STRUCTURE AT FS 621@ LBL 43.0 IS CRACKED AT FASTENER HOLES. C-CHECK REPLACED CRACKED FLOOR SUPPORT STRUCTURE @ FS 621 LBL 43.0 IAW REO.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT FLOOR SUPPORT STRUCTURE AT FS 621@ LBL 43.0 IS CRACKED AT FASTENER HOLES. C-CHECK REPLACED CRACKED FLOOR SUPPORT STRUCTURE @ FS 621 LBL 43.0 IAW REO.