Service difficulty report · Electrical Sys · Cndair CL6002C10

Difficulty date
June 13, 2014
Submitted
June 16, 2014
Operation
Air carrier
Aircraft
N750SK
Make and model
Cndair CL6002C10
Aircraft serial
10207
Aircraft time
28,166 hours, 16,748 cycles
Part
Electrical Sys
Condition
Malfunctioned
Stage of operation
CR
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NR 1 IDG OFFLINE ENROUTE, AC BUSS 1. AC ESS BUSS DID NOT TRANSFER TO IDG 2 AND AC ESS TRANSFER SWITCH WOULD NOT SWITCH POWER TO AC BUSS 2. POWER RETURNED TO ALL BUSES AFTER STARTING APU BUT ELECTRICAL SYNOPTIC PAGE STILL SHOWED BUSSES NOT POWERED AND NO ASSOCIATED FLOW LINES. RESET NR 1 GENERATOR, ALL INDICATIONS BECAME NORMAL ON GROUND. PERFORMED VISUAL INSPECTION OF NR 1 AND NR 2 IDG OIL SYSTEMS AND INSPECTED APU OIL LEVEL AND FOUND TO BE WITHIN LIMITS IAW AMM. PERFORMED OPS TEST OF THE AC AUTOMATIC POWER TRANSFER CIRCUITS, OPS CHECK GOOD IAW AMM.