What was found
DURING NDT MLG TRUNNION INSPECTION, FOUND CRACK ON FWD RT MLG DOOR FITTING AT TOP HOLE, 7 O'CLOCK POSITION. REPAIRED IAW SRM AND REO.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING NDT MLG TRUNNION INSPECTION, FOUND CRACK ON FWD RT MLG DOOR FITTING AT TOP HOLE, 7 O'CLOCK POSITION. REPAIRED IAW SRM AND REO.