What was found
ADM #2757. 3 " FORWARD OF FS613.0 AND 6" BELOW WL72.5 (ABOVE AND IN BETWEEN FORWARD AND CENTER BAGGAG BAY DOORS). DENT APPROXIMATELY 1" WIDE AND 0.025" DEEP. PLOT, MAP, AND EVALUATE DAMAGE IF WITHIN ACCEPTABLE LIMITS OR REWORKED, ELIMINATE EVIDENCE USING STANDARD ACFT PRACTICES. (C-CHECK) RO 2/14/2020 FABRICATED AND INSTALLED REPAIR DOUBLER ON SKIN BETWEEN FS 587-FS 620.95 AND STR 16L-STR 18L REF REO. COMPLIED WITH A PRESSURIZATION LEAK CHECK OF THE REPAIR AREA. REF. CRJ900 AMM. NO LEAKS NOTED. REFERENCE THE CONTINUE CARD FOR DETAILS.