What was found
GEAR DISAGREE AFTER TAKEOFF. NOSE GEAR WOULD NOT RETRACT. (FLT#5749) FO: 03/05/2019 CLOSED REMOVED AND REPLACED NLG SELECTOR VALVE IAW AMM. OPS CHECK GOOD AT THIS TIME. LEAK CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GEAR DISAGREE AFTER TAKEOFF. NOSE GEAR WOULD NOT RETRACT. (FLT#5749) FO: 03/05/2019 CLOSED REMOVED AND REPLACED NLG SELECTOR VALVE IAW AMM. OPS CHECK GOOD AT THIS TIME. LEAK CHECK GOOD.