As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WHILE PERFORMING TENSION CHECK OF THE AILERON CONTROL CABLES FOUND THE LH O/B FUSELAGE CABLE TO BE OUT OF LIMITS. THE MEASUREMENT IS 145 AT 80 DEGREES THE ALLOWABLE MEASUREMENT IS 120-130 AT 80 DEGREES. (C-CHECK) RO 10/16/2019 PERFORMED RIGGING OF THE LH FUSELAGE CONTROL CABLES IAW AMM.