As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WHILE PERFORMING TENSION CHECK OF THE AILERON CONTROL CABLES FOUND THE R/H I/B FUSELAGE CABLE TO BE OUT OF LIMITS. THE MEASUREMENT IS 100 AT 80 DEGREES, THE ALLOWABLE MEASUREMENT IS 120-130 AT 80 DEGREES (C-CHECK) RO: 10/16/2019 PERFORMED RIGGING OF THE RH AILERON FUSELAGE CONTROL CABLES IAW AMM.