What was found
WHILE PERFORMING TENSION CHECKS OF THE AILERON CONTROL CABLES FOUND THE LH I/B CONTROL COLUMN CABLE TO BE OUT OF LIMITS. THE MEASUREMENT IS 55 AT 80 DEGREES. THE ALLOWABLE MEASUREMENT AT 80 DEGREES IS 65-75 (C-CHECK) RO: 10/16/2019 LH I/B AND O/B CONTROL COLUMN CABLES ARE THE SAME CIRCUIT AND WERE RIG ON OTHER CARD.