As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WHILE PERFORMING TENSION CHECKS OF THE AILERON CONTROL CABLES FOUND THE RH O/B CONTROL COLUMN CABLE TO BE OUT OF LIMITS. THE MEASUREMENT IS 60 AT 80 DEGREES. THE ALLOWABLE MEASUREMENT AT 80 DEGREES IS 65-75 (C-CHECK) RO: 10/16/2019 PERFORMED TENSIONING OF THE RH CONTROL COLUMN IAW AMM.