What was found
TOP OF INTERCOSTAL CORRODED AT STGR21L BEWTEEN FS333.00 AND FS349.00, MARKED (C-CHECK) RO 01/07/2020 REMOVED CORROSION FROM TOP OF INTERCOSTAL AT STR 21 LH BETWEEN FS 333.00-349.00 REF CRJ 200 SRM. ORIGINAL MATERIAL THICKNESS IS 0.063" REF BOMBARDIER DWG. MINIMUM REMAINING THICKNESS IS 0.048" FOR A LOSS OF 0.015" FOUND TO BE OUT OF ALLOWABLE LIMITS REF CRJ200 SRM. INSTALLED REPLACEMENT INTERCOSTAL BETWEEN FS333.00 AND FS349.00 AT STR 21L REF: BOMBARDIER DWG, CRJ200 SRM.